EASY™ Basic Kits.
Patented, zero-drill exterior mounting hardware. Select your home’s siding foundation below to configure your setup.
EASY Basic Kit
Establishes your foundational exterior interface. Deploys the zero-drill, mechanical cam-lock Base Unit alongside the Universal Hook Accessory in seconds. Executes a verified 35lb dynamic load-bearing anchor directly on standard 1/4"–5/16" fiber cement lap planks, shingles, and shingle panels (James Hardie®, Nichiha®, Allura®) with zero damage.
Per-Unit Payload:
- • EASY Base Unit (Assembled 35lb Cam-Lock)
- • Universal Hook (Modular Secondary Interface)



EASY™ Vinyl Interface
Zero drilling, zero penetration, zero siding damage. Engineered specifically for standard hollow-backed horizontal vinyl lap siding. Slides directly beneath open bottom hem channels in seconds—delivering a calibrated 10lb hold while floating naturally with seasonal thermal expansion so panels never warp or buckle.
Per-Unit Payload:
- • EASY™ Vinyl Interface (Zero-Tool 10lb Seam Hook)
- • Universal Hook (Architectural White Modular Interface)
The Math is Absolute.
Legacy hardware is defined by its hidden penalties—travel time, specialized tools, and permanent exterior damage. The EASY Fiber Cement system pays for itself on the very first deployment.
EASY™ Fiber Cement
Adhesive Hooks
Not Exterior Rated
Drilled Screws
& Wall Anchors
(Inc. Travel & Research)
Measuring & Layout
Measuring & Layout
+ Risk Blind Utility Strike
(Fresh Adhesive Strips)
PRO: $100+ (Repairs)
EASY™ Vinyl Interface
Stamped Wire Hooks
Commodity Bent Wire
Drilled Screws
& Wall Fasteners
(Wrestling into seam)
(Drill & measuring)
to force seam open
& Silicone Sealants
(Flexes & drops gear)
(Tears siding under load)
panel drip hem
+ Causes heat warping
upon extraction
(Replace whole courses)
5-Step Tool-Free Installation.
Select your siding foundation below to view step-by-step engagement checks, removal tips, and cladding guidelines.
Seat Open Base Under Siding Course
Start with the cam lever swung fully upward in the open position. Slide the backing blade up behind the bottom overlap edge of any fiber cement lap plank or shingle course until the horizontal shelf rests flush against the bottom edge of the course.
Lock the Cam Lever Flush (One-Handed)
Press the cam lever downward with one hand until it seats flush with the chassis. As the rear cam profile contacts the backing tab, it depresses the adhered rubber-composed friction pad firmly into the surface face of the siding to lock in maximum contact grip.
Align Your Modular Accessory
Confirm the cam lever sits flush. Position the Universal Hook—or any modular EASY™ accessory, such as a camera mount or magnet array—at the top of the base to engage its outer surface guide rails.
Engage Onto Inverse-Dovetail Stops
Glide the accessory straight downward onto the front engagement face until the upper inverse-dovetail teeth on the backside (at the 10 o’clock and 2 o’clock positions) seat firmly at their stop points.
Verify Flush Fit & Safely Hang Up to 35 lbs
Confirm the base and hook sit level and flush against the plank. Your mount is ready for string lights, smart cameras, wreaths, tarps, or contractor jobsite gear up to a conservative 35-lb dynamic load.
One-Handed Removal & Relocation
Disengage effortlessly with one hand—glide the accessory straight up and off the front face, lift the bottom edge of the cam lever upward to release tension, and slide the base down cleanly without damaging the siding.
Important Storage Rule
Whenever unmounted, always store your Fiber Cement Cam-Lock Base with the cam lever in the OPEN (unlocked) position to preserve long-term polymer spring tension.
MIL-SPEC Materials & Siding Notes
Built with MIL-SPEC DuPont™ Zytel® UV polymer, a marine-grade stainless steel pin, and a high-grip rubber-composed friction pad for fiber cement lap planks, shingles, and shingle panels. Cedar Note: Properly dimensioned cedar shingle siding accepts the base, though long-term compression imprinting on softer wood fibers remains unverified. Never mount on hollow vinyl siding (use the EASY™ Vinyl Siding Interface).
Pre-Attach Accessory in Hand (Flex Tongue Tip)
For the Universal Hook and compact adapters, attach the accessory in hand first so the hanging plate cannot shift. While gliding it down the front rails, gently flex the flexible upper tongue backward so the backside inverse-dovetail teeth at 10 and 2 o’clock pass smoothly to their stops.
Locate Seam & Insert Hook Horizontally
Locate an actual interlocking panel seam—on traditional double-lap vinyl siding, this occurs on every other shadow line rather than the solid middle panel crease. Tilt the assembly nearly horizontal and slip the curved upper hook tip upward behind the bottom butt edge of the upper course.
Cradle the Concealed Interlocking Channel
Guide the curved hook upward and inward into the joint until the tip clears the lower lock lip and seats smoothly inside the concealed interlocking hem channel without prying or forcing the hollow vinyl panel.
Pivot Assembly Downward Flush to Wall
Rotate the Interface body smoothly downward toward the siding face. As the plate pivots vertical, the upper hook locks naturally inside the concealed seam channel while protecting the vinyl profile from creasing or flexing.
Verify Flush Fit & Safely Hang Up to 10 lbs
Confirm the upper tongue sits squarely in the seam and the Interface hangs flat against the course below. Your mount is ready for smart cameras, string lights, wreaths, or flags up to a conservative 10-lb calibrated load.
Oversized Cameras: Hang Bare Interface First
For bulky cameras that are awkward to maneuver in hand during seam insertion, hook the bare Interface into the seam first using Steps 02–04. Steady the hanging plate with one hand while gliding the camera mount down onto the front rails with the other.
Instant Damage-Free Removal & Swaps
Unhook in seconds by pivoting the bottom of the Interface upward away from the wall and slipping the curved hook cleanly out of the seam. To swap accessories in hand, slide the accessory upward off the rails (flexing the upper tongue slightly backward if needed for smooth clearance).
Cladding Protection & US Manufacturing
Precision-manufactured in Oregon in Architectural White and tailored for hollow vinyl profiles—eliminating drills, screws, adhesives, moisture barrier punctures, and panel creasing.
Siding Profile Compatibility
Built for traditional horizontal double-lap and single-lap interlocking vinyl siding (engages every other shadow line seam on double-lap profiles). Does not engage decorative middle panel creases, sealed or glued foam-backed composite planks, or rigid fiber cement courses (use the EASY™ Fiber Cement Cam-Lock Base for fiber cement).